General Maintenance Coating & High Performance Maintenance Coatings
Harlepoxy Primer Industrial Grade 1
Grade |
Performance Grade |
Drying System |
Air Drying Under Coat |
Description |
It is a two pack primer based on Epoxy resin and Zinc Phosphate or Zinc Chrome Pigment. It gives a excellent protection in chemical and corrosive atmosphere. |
Volume Solids |
42 /-2 % |
DFT |
30-35 µm per coat |
Mixing Ratio |
BASE : HARDNER 4:1 OR 3:1 |
Pot Life |
4 Hrs Minimum |
Spreading Rate |
12-14 m²/L |
Surface Dry |
0.5-1 hr. @ 30°C and 65% relative humidity |
Hard Dry |
8-10 hrs @ 30°C and 65% relative humidity |
Tack Free |
Overnight |
Subsequent Coat |
As per substrate condition recommended coating system |
Recoating Time - MIN |
10 Hrs |
Recoating Time - MAX |
7 Days |
Finish |
Smooth Uniform matt |
Shelf Life |
Base: 1 year Hardner: 6 months |
Surface Preparation |
New Surface: Surface should be free from oil, grease, salt and any other foreign matter. Clean the surface mechanically or manually. Maintanance: Manual cleaning to remove any loose particle oil, grease and any other foreign matter. |
Applicable Industry |
Packaging/Automobile-OEM Engineering/ General Maintainance/Electronic and Electrical |
Application Method |
Conventional Air Spray/ Brushing / Airless Spray |
Gel Time |
4 Hrs Minimum |
Recommended Thinner |
Harlepoxy Thinner |
Suggested Use |
For high quality protective coating , Fabrication Industries, Machine Tool Industry, chemical industry, steel plants and Automobile Industry |
Harlepoxy Primer Industrial Grade 2
Grade |
Industrial Grade 2 |
Drying System |
Air Drying Under Coat |
Volume Solids |
42 /-2 % |
Description |
It is a two pack primer based on Epoxy resin and polyamide curing agent. It gives a good protection in chemical and corrosive atmosphere. |
DFT |
30-35 µm per coat |
Mixing Ratio |
BASE : HARDNER 4:1 OR 3:1 |
Pot Life |
4 Hrs Minimum |
Spreading Rate |
12-14 m²/L |
Surface Dry |
0.5-1 hr. @ 30°C and 65% relative humidity |
Hard Dry |
12-14 hrs @ 30°C and 65% relative humidity |
Tack Free |
Overnight |
Subsequent Coat |
As per substrate condition recommended coating system |
Recoating Time - MIN |
10 Hrs |
Recoating Time - MAX |
7 Days |
Finish |
Smooth Uniform matt |
Shelf Life |
Base: 1 year Hardner: 6 months |
Surface Preparation |
New Surface: Surface should be free from oil, grease, salt and any other foreign matter. Clean the surface mechanically or manually. Maintanance: Manual cleaning to remove any loose particle oil, grease and any other foreign matter. |
Applicable Industry |
Packaging/Automobile-OEM Engineering/ General Maintainance/Electronic and Electrical |
Application Method |
Conventional Air Spray/ Brushing / Airless Spray |
Gel Time |
4 Hrs Minimum |
Recommended Thinner |
Harlepoxy Thinner |
Suggested Use |
For Good quality protective coating , Fabrication Industries, Machine Tool Industry, chemical industry, steel plants and Automobile Industry |
Harlepoxy Primer Maintenance Grade
Grade |
Industrial Grade 2 |
Drying System |
Air Drying Under Coat |
Description |
It is a two pack primer based on Epoxy resin and polyamide curing agent. It gives a fair protection in chemical and corrosive atmosphere. |
Volume Solids |
38 /-2 |
DFT |
30-35 µm per coat |
Mixing Ratio |
BASE : HARDNER 4:1 OR 3:1 |
Pot Life |
4 Hrs Minimum |
Spreading Rate |
11-13 m²/L |
Surface Dry |
0.5-1 hr. @ 30°C and 65% relative humidity |
Hard Dry |
12-14 hrs @ 30°C and 65% relative humidity |
Tack Free |
Overnight |
Subsequent Coat |
As per substrate condition recommended coating system |
Recoating Time - MIN |
10 Hrs |
Recoating Time - MAX |
7 Days |
Finish |
Smooth Uniform matt |
Shelf Life |
Base: 1 year Hardner: 6 months |
Surface Preparation |
New Surface: Surface should be free from oil, grease, salt and any other foreign matter. Clean the surface mechanically or manually. Maintanance: Manual cleaning to remove any loose particle oil, grease and any other foreign matter. |
Applicable Industry |
Packaging/OEM Engineering/ General Maintainance/Electronic and Electrical |
Application Method |
Conventional Air Spray/ Brushing / Airless Spray |
Gel Time |
4 Hrs Minimum |
Recommended Thinner |
Harlepoxy Thinner |
Suggested Use |
For fair quality protective coating , Fabrication Industries, Machine Tool Industry, steel plants,etc |
Harlepoxy Primer One Pack
Grade |
Industrial Grade 1 |
Drying System |
Air Drying Under Coat |
Description |
It is a single pack primer based on specialised Epoxy resin and curing agent. It gives a good protection in chemical and corrosive atmosphere. |
Volume Solids |
42 /-2 % |
DFT |
30-35 µm per coat |
Mixing Ratio |
N/A |
Pot Life |
N/A |
Spreading Rate |
12-14 m²/L |
Surface Dry |
15-20 mints. @ 30°C and 65% relative humidity |
Hard Dry |
6-8 hrs @ 30°C and 65% relative humidity |
Tack Free |
Overnight |
Subsequent Coat |
As per substrate condition recommended coating system |
Recoating Time - MIN |
10 Hrs |
Recoating Time - MAX |
7 Days |
Finish |
Smooth Uniform to matt |
Shelf Life |
1 Year |
Surface Preparation |
New Surface: Surface should be free from oil, grease, salt and any other foreign matter. Clean the surface mechanically or manually. Maintanance: Manual cleaning to remove any loose particle oil, grease and any other foreign matter. |
Applicable Industry |
Packaging/Automobile-OEM Engineering/ General Maintainance/Electronic and Electrical |
Application Method |
Conventional Air Spray/ Brushing / Airless Spray |
Gel Time |
N/A |
Recommended Thinner |
Harlepoxy Thinner |
Sugested Use |
For moderate quality protective coating , Fabrication Industries, Machine Tool Industry, chemical industry, steel plants. |
Harlepoxy Clear Primer
Grade |
Industrial Grade 1 |
Drying System |
Air Drying Under Coat |
Description |
It is a two pack clear primer based on Epoxy resin and polyamide curing agent. It gives a good protection in chemical and corrosive atmosphere. |
Volume Solids |
38 /-2 % |
DFT |
25-30 µm per coat |
Mixing Ratio |
BASE : HARDNER 2:1 OR 3:1 |
Pot Life |
5 Hrs Minimum |
Spreading Rate |
12-15 m²/L |
Surface Dry |
0.5-1 hr. @ 30°C and 65% relative humidity |
Hard Dry |
12-14 hrs @ 30°C and 65% relative humidity |
Tack Free |
Overnight |
Subsequent Coat |
As per substrate condition recommended coating system |
Recoating Time - MIN |
10 Hrs |
Recoating Time - MAX |
7 Days |
Finish |
Smooth Uniform Glossy |
Shelf Life |
Base: 12 months Hardner: 12 months |
Surface Preparation |
New Steel: Recommended for abrasive blasting to Sa2½. If steel is coated by shop primer, clean all damages to shop primer and also clean the surface free from oil grease and any other foreign particles. Maintenance: Remove oil, grease etc with a detergent wash. Remove salt and other contaminants by high pressure fresh water hosing. Remove all rust and loose materials by abrasive blasting or mechanical cleaning. Dust off residues. For best results remove all loose rust by wire brushing and chipping. |
Applicable Industry |
Packaging/construction industry/ General Maintainance/Electronic and Electrical |
Application Method |
Conventional Air Spray/ Brushing / Airless Spray |
Gel Time |
5 Hrs Minimum |
Recommended Thinner |
Harlepoxy Thinner |
Suggested Use |
For good quality concrete primer. It protects concrete from ingress of moisture and fortifies the concrete strength. |